Chemence Ltd
An anaerobic retainer adhesive based on methacrylate compounds used for bonding and sealing threaded fasteners. This product poses hazards through skin irritation, serious eye damage, and respiratory irritation. Avoid direct contact and ensure adequate ventilation during handling.
27813-02-1,79-10-7,15625-89-5,80-15-9,99-97-8,114-83-0
English
GHS/CLP
14 April 2014
Key safety data extracted from the official Safety Data Sheet
Bathe the eye with running water for 15 minutes. Transfer to hospital for specialist examination immediately.
Remove all contaminated clothes and footwear immediately unless stuck to skin. Wash immediately with plenty of soap and water. Seek medical attention if irritation persists.
Remove casualty from exposure to fresh air, ensuring personal safety. Seek medical attention if symptoms develop.
Do not induce vomiting. Wash out mouth with water. If conscious, give half a litre of water to drink. Consult a doctor immediately.
Use self-contained breathing apparatus or gas/vapor filter (type A for organic vapours EN141) in case of emergency or when mist generation occurs
Wear neoprene or nitrile gloves. Do not use PVC gloves as they absorb methacrylates
Safety glasses with side-shields required. Ensure eye bath equipment is available on premises
Wear protective clothing to prevent splashing and contact with skin
Store in cool, well-ventilated area away from sources of ignition and direct sunlight. Keep container tightly closed in original packaging only.
Disclaimer: The information displayed on this page is derived from the manufacturer's Safety Data Sheet. Always refer to the official SDS document for complete and up-to-date safety information. Sevron is not responsible for any inaccuracies in the displayed data.